ETCR9100 AC 0.00mA to 600A H/L Voltage Clamp Leaker Meter with High and Low Voltage Clamp Ammeter Clamp Size 33mm LCD Display 99 Groups Data Storage
R 31,150
Availability: Currently in Stock
Delivery: 10-20 working days
ETCR9100 AC 0.00mA to 600A H/L Voltage Clamp Leaker Meter with High and Low Voltage Clamp Ammeter Clamp Size 33mm LCD Display 99 Groups Data Storage
★Peak Hold: Automatically hold the test value at a high point. Press the PEAK button in the test mode until the PEAK lamp lights up. The peak hold function is enabled; Data Hold: Press HOLD key to hold data in test mode, "HOLD" symbol display; Data review: "MR" symbol indicates that the data can be read up and down; Overflow display: Over range overflow function: "OLA" symbol display
★Line voltage: Line test below 60KV (with 5 sections insulation rod operation); Voltage alarm: When the battery voltage is lower than 4.8V, the battery voltage is low;Insulation strength: Section 5 between insulation rod and high-voltage detector shell: AC 100kV/rms; between high-voltage detector shell and iron core: AC1000V/rms
★Resolution: 0.01mA; Accuracy: ±1%rdg±5dgt (23°C±5°C, 80%r or less);Measurement method: Clamp CT, non-contact measurement, integral method; Automatic shutdown: 15 minutes or so automatically shut down
★The ammeter is composed of a high voltage detector and five high-voltage insulated rods. The insulation rod is light, with features such as moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation, and detachability. Instrument has peak hold, data retention, data storage (99 groups) and other functions
★ETCR9100 high and low voltage clamp ammeter for low voltage AC leakage current and current measurement up to 60kV. Range: 0.00mA~600A, jaw size is Φ33mm, special alloy for current clamp, magnetic shield technology, strong anti-jamming ability, ensure Measurement accuracy and stability
Shipping Policy : Battery and Liquid not Included During the Shipping Technical Specifications * Function: high and low voltage AC leakage current, current measurement * Clamp size: Φ33mm * LCD size: 47mm x 28.5mm (with backlight) * Range: AC 0.00mA~600A * Resolution: 0.01mA * Accuracy: ±1%rdg±5dgt (23°C±5°C, 80%r or less) * Data Storage: 99 Groups * Automatic shutdown: 15 minutes or so automatically shut down * Working environment: -20°C~40°C; 80% rh * Storage environment: -10 °C ~ 60 °C; 70% rh below * Structure: Anti-drip II * Measurement method: Clamp CT, non-contact measurement, integral method * Frequency: 50Hz, 60Hz automatic identification * Shift: Automatic shifting * Peak Hold: Automatically hold the test value at a high point. Press the PEAK button in the test mode until the PEAK lamp lights up. The peak hold function is enabled. * Data Hold: Press HOLD key to hold data in test mode, "HOLD" symbol display * Data review: "MR" symbol indicates that the data can be read up and down * Overflow display: Overrange overflow function: "OLA" symbol display * Line voltage: Line test below 60KV (with 5 sections insulation rod operation) * Measurement time: 0.5 seconds/time * Voltage alarm: When the battery voltage is lower than 4.8V, the battery voltage is low * Insulation rod size: Φ32mm, 1m/section (5 sections) * Insulation strength: Section 5 between insulation rod and high-voltage detector shell: AC 100kV/rms; between high-voltage detector shell and iron core: AC1000V/rms * Clamp meter quality: Detector: approx. 335g, total instrument mass: approx. 7Kg (with insulation rod) * Power supply: DC 6V (7# battery 1.5V x4)(Battery not included in the package) * Clamp meter size: Lx W x T: 245mmX68mmX40mm