RAINPAL RBIO125F Rain Barrel Inlet Outlet DIY Kit (HDPE Fine 2” Bung to 1-1/4” Barbed Fitting and Brass Ball Valve Spigot w/Bulkhead Fitting)
R 1,204
or 4 x payments of R301.00 with
Availability: Currently in Stock
Delivery: 10-20 working days
RAINPAL RBIO125F Rain Barrel Inlet Outlet DIY Kit (HDPE Fine 2” Bung to 1-1/4” Barbed Fitting and Brass Ball Valve Spigot w/Bulkhead Fitting)
ATTENTION: REVERSE THREADED FITTING NUT, Turn CLOCKWISE to LOOSEN.
Contain RAINPAL RBI125F HDPE Rain Barrel Inlet Port and RAINPAL RBS022LF Brass Rain Barrel Ball Valve Spigot w/ Bulkhead Fitting
HDPE Fitting: For 2" Bung Cap with Fine Threads (Threaded Part Measure about 2.25 inches in Diameter, Distance between Adjacent Threads is approx 3/32 inch), 1.25" Barbed Side Accepts Any Pipe with 1.25“ Inside Diameter
Brass Spigot: Contain less than 0.25% lead, lead free compliant. Bulkhead fitting need 1-1/4 inch diameter hole to install. Fit up to 0.4 inch thickness wall. Left Handed Nut(Reverse Threaded) for easy installation
Installation Instructions:
Tools Needed: 1-1/4 inch saw, Power drill, Knife, Pipe Wrench and Thread Tape
1. Center the hole saw drill bit 3-12 inch above the bottom of the barrel (lower position makes you use most of the water, higher position keeps more water and make barrel more stable, higher position also make it easy to dispense the water without using a stand). Drill 1-1/4 inch hole on rain barrel(use eye protection when operating power tool). Then remove any debris, and use a knife to smooth the edges. 2. If your barrel has an open top, you can install the fitting with nut inside or outside. If your barrel has a small opening like a bung hole on top: Drop the bulkhead fitting male piece with the gasket. Roll the barrel; pick up the fitting through the hole you drilled from outside. Or to prevent the gasket from separating from the fitting, you can hook the fitting with a wire, and then run the wire down to the drilled hole. 3. Install the bulkhead fitting nut, turn counter clockwise to tighten, after hand tight, use a pipe wrench to tighten a bit more. 4. Wrap the BASE of spigot threads with Teflon tape (5 rounds) and install the spigot clockwise. If the spigot is not in a desired position, loosen the fitting nut, turn the spigot to the right position then tighten the fitting nut. TIP: for easy un-installation later, only lightly tighten the spigot/ball valve. When uninstall, remove the ball valve first. California prop 65 warning: California prop 65 warning: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.
Contain less than 0.25% lead, lead free compliant. For more information about lead free complianct, please visit epa.gov