Turbine Flow Meter, Flow Water Meter 15-120L/min 1" NPT Digital Fuel Meter Water Flow Meter Diesel Oil Fuel Flow Meter, Fuel Flow Meter
R 3,088
or 4 x payments of R772.00 with
Availability: Currently in Stock
Delivery: 10-20 working days
Turbine Flow Meter, Flow Water Meter 15-120L/min 1" NPT Digital Fuel Meter Water Flow Meter Diesel Oil Fuel Flow Meter, Fuel Flow Meter
MODULAR DESIGN FITS FOR OUTPUT MODULES--Modular design makes it suitable for use with output modules, sensors and remote transmitters
LIGHT WEIGHT AND COMPACT SIZE OFFERS CONVENIENT OPERATION AND INSTALLATION--Light weight, compact structure, easy to install
ALLOWS CLEAR READING AND HIGH ACCURACY MEASURING--Intuitive clear reading, high reliability, measuring accuracy is ±1%
SHOWS INSTANTANEOUS AND CUMULATIVE FLOW--High-definition displays show both instantaneous and cumulative flow
WIDELY APPLICATIONS FOR LIQUIDS' FLOW METER TESTING--Can be widely used to measure diesel, urea, kerosene, gasoline, etc
Specification: Thread size: 1inch NPT female Material: Plastic Color: Blue Repetition: ±0.5% Measure accuracy: ±1% Maximum working pressure: 20BAR Flow range: 15-120L / Min Single count: 0.00-9999.9 Total cumulative count: 0-99999 Error coefficient: 0.1000-9.9999 Unit: L / GAL / PTS / QTS Working temperature: -10°C ~ +60°C(14°F~140°F) Operating voltage: 2.3-3.3V Application: Diesel, urea, kerosene, gasoline Battery type: 2 x AAA LRO3 batteries Weight: 270g / 9.5oz (approx.)
Malfunction and solution: The flow meter is not accurate. 1. The method of field calibration is not correct.  Calibrate again. 2. The flow rate on the meter is below the lowest. Increase the flow rate. 3. The flow meter is blocked by the dry liquid. Take out the impeller and clean it carefully and make sure the impeller turns freely. 4. The impeller is wrapped by the sealing material. Remove the meter and make sure the impeller turns freely. 5. Too close to the impeller.  Install properly. 6. Too close to the motor or electronic noise environment  Install properly. The reading numbers faded or blanked out. 1.Battery is exhausted or not connected Check the batteries or even replace them. Flow rate is normal but the meter can not count. Press the button of DISPLAY, the meter starts. 1. Field calibration is not correct. Calibrate again. 2. The impeller is blocked or damaged.  Remove the meter and make sure the impeller turns freely. 3.The impeller is wrapped by the sealing material.  Remove the meter and make sure the impeller turns freely. Flow rate is low and the meter can not count. Press the button of DISPLAY, the meter starts.Â